Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit: T06CM03643

Parcel: 114517060


Addresses:

8882 E HONEYBEAR PL

Inspection Status: Approved

Inspection History: EXT METAL CLIPS/EXT SHEATHING

Date Description Inspector Results Comments
12/22/2006 EXT METAL CLIPS/EXT SHEATHING Approved IVRS - Inspection :*
12/08/2006 EXT METAL CLIPS/EXT SHEATHING Partial Approval IVRS - Inspection :*
1) LEDGER CLIPS OK
2) NAIL OFF STD8 STRAPS WITH 16D SINKERS (.148 X 3 1/4 ) NOT .131 X 3 1/4
3) PLAN CALLS FOR 5/8 ABS, NOT 1/2". HAVE PLAN CHANGED OR USE 5/8 RED HEADS
4) ADD ANCHORS WEST WALL WHERE MARKED