Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit: T06CM03642

Parcel: 141014320


Addresses:

5474 S CIVANO BL


Inspection Status: Approved

Inspection History: ROOF NAILING

Permit Number - T06CM03642

Inspection Description - ROOF NAILING

Inspection Status - Approved

Date Description Inspector Results Comments
09/28/2006 ROOF NAILING Approved IVRS - Inspection :*
09/26/2006 ROOF NAILING Denied IVRS - Inspection :
See detailed listing on site.| 999*
- PROVIDE ACCESSIBILITY FOR ROOF INSPECTION.
- WORK SHALL REMAIN ACCESSIBLE AND EXPOSED FOR INSPECTION PURPOSES UNTIL APPROVED.
09/22/2006 ROOF NAILING Partial Approval IVRS - Inspection :*
1) TWO 4' X 8' SHEETS OF ROOF OSB TURNED PARALELL TO ROOF RAFTERS 4' EDGE OF DECKING ALWAYS NEEDS TO BE SUPPORTED ADD BLKS EA. END AND AT MID POINT A FEW MISSIED NAILS MARKED IN BLACK
2) NOTE: DIS-SIMILAR METAL CU./IRON PIPE-USE BRASS FITTING NEUTRAL METAL