Inspection Status: Approved
Inspection History: FRAMING
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 10/24/2006 | FRAMING | Approved | IVRS - Inspection :* | |
| 10/20/2006 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) STAPLE STUCCO MESH 6" ON CENTER 2) ELECTRICAL BOXES MUST BE WITHIN 1/4" OF SURFACE OF MESH 3) BANG PLATES ON PEX IN KITCHEN 4) FIRE STOP ALL TOP PLATE PENETRATIONS 5) FILL DWV 6) NO SCREWS IN DRYER DUCT 7) BANG PLATE AT DRYER DUCT 8) SUPPORT VENT TO ROOF OVER MASTER BATH 9) REPLACE RED HEADS UNDERSET 10) REPLACE DAMAGED LINE SET 11) REINFORCE TOP PLATE AT LINE SET 12) REPLACE BLOWN FIREBLOCK IN HALLWAY |
|
| 10/06/2006 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) STAPLE STUCCO MESH 6" ON CENTER 2) ELECTRICAL BOXES MUST BE WITHIN 1/4" OF SURFACE OF MESH 3) VACUUM BREAKER AT HOSE BIB 4) BLOCK MECH BOOTS 5) EXCESSIVE WATER ON FLOOR AND NO DWV TEST 6) STOPPED INSPECTION-HOUSE NOT READY |