Inspection History Details
Inspection Status: Approved
Inspection History: ELECTRIC - INTERMEDIATE
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 03/30/2007 | ELECTRIC - INTERMEDIATE | Approved | IVRS - Inspection :* OK INTERIOR ELECTRICAL COVER |
|
| 03/20/2007 | ELECTRIC - INTERMEDIATE | Not ready for Inspection | IVRS - Inspection :* 1. STRAP AND SECURE NM CABLES 334.30 USE APPROVED SUPPORTS. 2. JUNCTION BOXES TO BE ACCESSIBLE 3. FINISH PREVIOUS ITEMS. |
|
| 03/07/2007 | ELECTRIC - INTERMEDIATE | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1. INSTALL NAIL PLATES AS NEEDED. 2. MAX 15 AMP ON 14GA WIRE 3. SMOKE DETECTORS NOT MOUNTED PROPERLY - CHECK/SUPPLY INSTALLATION INSTRUCTIONS. 4. CEILING FAN TO LOW, FAN RATED BOX 5. PROTECT ROMEX FROM SHARP EDGES @ STUDS 6. HAVE OVERFILLED J-BOXES 7. GROUND ALL METAL BOXES |
|
| 02/20/2007 | ELECTRIC - INTERMEDIATE | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1. NEED APPROVED PLANS THAT INCLUDE ENTIRE SCOPE OF WORK. 2. ALL WIRING INCLUDED IN NEWLY APPROVED PLANS NEED TO BE EXPOSED AT TIME OF INSPECTION. 3. NEED LICENSED ELECTRICAL CONTRACTOR DOING WORK. |
|
| 12/13/2006 | ELECTRIC - INTERMEDIATE | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1. AREAS COVERED WITHOUT INSPECTION |