Inspection History Details
Inspection Status: Approved
Inspection History: BUILDING - FINAL
Permit Number - T06CM03623
Inspection Description - BUILDING - FINAL
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
12/08/2006 | BUILDING - FINAL | Approved | IVRS - Inspection :* | |
12/05/2006 | BUILDING - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) POST ADDRESS ON BLDG PERMANENT 2) BUBBLE COVER REQUIRED ON EXTERIOR GFI OUTLET 3) NEGATIVE FLOW ON PTR LINE 4) PAINT ABS ROOF VENTS 5) ANTI-TILT MISSING AT RANGE 6) OUTLET REQUIRED OVER 12" COUNTER CABINET 7) DBL KEYED DEAD BOLT NOT ALLOWED ON EXIT DOOR |
|
12/01/2006 | BUILDING - FINAL | Partial Approval | IVRS - Inspection :* |