Inspection History Details
Inspection Status: Approved
Inspection History: FRAMING
Permit Number - T06CM03616
Inspection Description - FRAMING
Inspection Status - Approved
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 10/23/2006 | FRAMING | Approved | IVRS - Inspection :* | |
| 10/17/2006 | FRAMING | Partial Approval | IVRS - Inspection :* 1) 4 X 4 BOX TO BE 3/8" BEYOND LATHE OR INSTALL BOX EXTEND ? (SEE MARKS ON FLOOR) 2) ITEMS 2, 3, 4 AND 5 NOT COMPLETED |
|
| 10/10/2006 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) PUSH ROMEX FOR A/C THRU WALL 2) GARAGE TO HOUSE H.D.'S USED WRONG SIZE NAIL (K)=.131 8 COMMON ALL H.D.'S. H.D. ON EAST/WEST END OF WALL TO GO TO END OF WALL NOT 2'-0" IN, NAIL DBL STUDS VERT. 24" ON CENTER 3) AT REAR EXT. DOOR 4 X 4 ELECTRIC BOX COVERED WITH LATH ROMEX HANGING DOWN FROM CEILING 4) LOOSE BOTTOM PLATE AT LAV DRAIN MASTER, PEX TOO CLOSE TO CAN ABOVE LAV 5) HALL BATH CORNER NOT COMPLETE 6) BANG PLATE ROMEX FRONT BEDROOM 7) PENETRATIONS LATHE NOT CAULKED, LATHE INCOMPLETE THRU-OUT 8) UN-PULLED P.T. CABLE REAR |