Inspection History Details
Inspection Status: Cancelled
Inspection History: FRAMING
Permit Number - T06CM03615
Inspection Description - FRAMING
Inspection Status - Cancelled
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
09/22/2006 | FRAMING | Cancelled | IVRS - RI canceled | |
09/21/2006 | FRAMING | Approved | IVRS - Inspection :* | |
09/19/2006 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) WIRING FOR A/C NEEDS TO PENETRATE STUCCO MESH 2) SECURITY TERMINAL AT GARAGE MAN DOOR CAN'T SHARE STUD BAY WITH SWITCH BOX ON OPPOSITE SIDE 3) WIRE CUT UNDER FRONT WINDOW BAY 4) ANCHOR BOLT MISSING IN M. BATH 5) BANG PLATE AT L.R. PEX THROUGH TOP PLATE 6) FIREBLOCK BELOW KITCHEN HOOD VENT |