Permit: T06CM03587

Parcel: 136155430


Addresses:

8085 E SENATE ST


Inspection Status: Approved

Inspection History: FRAMING

Permit Number - T06CM03587

Inspection Description - FRAMING

Inspection Status - Approved

Date Description Inspector Results Comments
11/17/2006 FRAMING Approved IVRS - Inspection :*
10/24/2006 FRAMING Not ready for Inspection IVRS - Inspection :*
10/23/2006 FRAMING Not ready for Inspection IVRS - Inspection :*
10/20/2006 FRAMING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) NO DWV TEST
10/19/2006 FRAMING Denied IVRS - Inspection :
See detailed listing on site.| 999*
10/17/2006 FRAMING Partial Approval IVRS - Inspection :*
1) CAULK GAS PIPE
2) WIRE OUT OF WALL BEDROOM 2 CLOSET
3) FHA STRAPS 3" ABS OVER BORE KITCHEN
4) NO DWV WATER TEST
5) NO PRESSURE
6) CHANGE SLOPE WATER HEATER B-VENT
7) ADD SINGLE WALL CONNECTOR PIPE AT FURNACE