Inspection History: PLUMBING - INTERMEDIATE
Permit Number - T06CM03539
Inspection Description - PLUMBING - INTERMEDIATE
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
09/08/2006 | PLUMBING - INTERMEDIATE | Approved | IVRS - Inspection :* | |
08/17/2006 | PLUMBING - INTERMEDIATE | Denied | LAV MOVE OK WC MOVE IS OK, CLOSET FLANGE IS REQUIRED TO BE FASTENED TO FLOOR (DROP SOME BRASS SCREWS INTO FLANGE BEFORE CONCRETE). |
|
08/14/2006 | PLUMBING - INTERMEDIATE | Not ready for Inspection | IVRS - Inspection :* - MAKE CHANGE TO WC TRAP ARM, LEAVE EXPOSED FOR INSPECTION. - TEST VENTS - PROVIDE SUPPORT ON HORIZONTAL ABS AT 4' INTERVALS. - PROVIDE ISOLATION BETWEEN COPPER AND STUDS - REMOVE EXCESS FLUX FROM SOLDIER JOINTS W/DAMP RAG |