Permit: T06CM03539

Parcel: 108240810

Inspection Status: Approved

Inspection History: PLUMBING - INTERMEDIATE

Date Description Inspector Results Comments
09/08/2006 PLUMBING - INTERMEDIATE Approved IVRS - Inspection :*
08/17/2006 PLUMBING - INTERMEDIATE Denied LAV MOVE OK
WC MOVE IS OK, CLOSET FLANGE IS REQUIRED TO BE FASTENED TO FLOOR (DROP SOME BRASS SCREWS INTO FLANGE BEFORE CONCRETE).
08/14/2006 PLUMBING - INTERMEDIATE Not ready for Inspection IVRS - Inspection :*
- MAKE CHANGE TO WC TRAP ARM, LEAVE EXPOSED FOR INSPECTION.
- TEST VENTS
- PROVIDE SUPPORT ON HORIZONTAL ABS AT 4' INTERVALS.
- PROVIDE ISOLATION BETWEEN COPPER AND STUDS
- REMOVE EXCESS FLUX FROM SOLDIER JOINTS W/DAMP RAG