Permit: T06CM03536

Parcel: 118051830


Addresses:

1602 S VIA ELNORA

Inspection Status: Approved

Inspection History: FRAMING

Date Description Inspector Results Comments
11/21/2006 FRAMING Approved IVRS - Inspection :*
11/13/2006 FRAMING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) STAPLE WIRES 8" FROM BOXES
2) BLOCK 3 SIDES OF MECH BOOTS
3) COMPLETE BATH WIRING
4) MAKE-UP ALL OUTLET BOXES
5) TEST POTABLE WATER
6) INSTALL STUCCO MESH
11/01/2006 FRAMING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) TIGHTEN ALL RED HEADS
2) ANCHOR BOLTS MISSING IN BATH
3) STAPLE WIRES 8" FROM BOXES
4) ONE WIRE IN THREE GANG BOX ?
5) COMPLETE WIRING OVER LAV
6) PRESSURIZE WATER SUPPLY FOR TEST
10/24/2006 FRAMING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1. STRAP ALL BEAMS TO POSTS
2. STRAP CORNERS & BREAKS IN DOUBLE TOP PLATES
3. REPLACE BENT NAILS IN HOLD DOWNS
4. BLOCK EXISTING SHEATHING ON SHED ROOF 24" O.C WHERE GRAIN OF PLYWOOD IS PARALLEL TO RAFTERS.
5. ADDITIONAL ANCHOR BOLTS REQ'D @ JOINTS IN SILL PLATES.
6. FINAL FRAMING APPROVAL WILL NOT BE GIVEN PRIOR TO COMPLETION OF ALL INTERMEDIATES, FRAMING OF SKYLIGHTS AND PENETRATION TO HOUSE FOR FRENCH DOORS.