Inspection History Details
Inspection Status: Approved
Inspection History: BUILDING - FINAL
Permit Number - T06CM03518
Inspection Description - BUILDING - FINAL
Inspection Status - Approved
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 08/22/2006 | BUILDING - FINAL | Approved | IVRS - Inspection :* | |
| 07/28/2006 | BUILDING - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) SEAL OPEN KNOCKOUTS IN PANEL DEADFRONT 2) EAST LAUNDRY OUTLET HAS NO POWER 3) EXTERIOR CONDUIT OUTLETS NEED GFI PROTECTION 4) NEED HOODED LIGHT 5) FINISH WATER HEATER INSTALLATION |
|
| 07/24/2006 | BUILDING - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) NEED ALL ELECTRIC ON FOR INSPECTION AND ACCESS TO PANELS 2) NEED TO SHEETROCK LAUNDRY ROOM 3) DRYER VENT DUCT IS OVER SPANNED MAX 25' -5' FOR EACH 90 DEGREE ELBOW, -2 1/2' FOR EACH 45 DEGREE 4) NEED SMOKIES IN HALL AND ALL BEDROOMS 5) NEED 3/4" DRAIN ON TPR VALVE AND DRAIN NEEDS TO RUN IN DOWN DIRECTION TO EXTERIOR OF HOUSE 6) NEED COMBUSTION AND RELIEF AIR FOR HOT WATER HEATER |