Inspection History Details
Inspection Status: Approved
Inspection History: BUILDING - FINAL
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 04/19/2007 | BUILDING - FINAL | Approved | IVRS - Inspection :* | |
| 04/18/2007 | BUILDING - FINAL | Partial Approval | IVRS - Inspection :* 1) PLAN CALLS FOR FULLY SHIELDED FIXTURES 2 IN STUDIO AND 4 IN MAIN RESIDENCE-THESE ARE NOT FULLY SHIELDED 2) DO NOT KNOW MANUFACTURER ? OR CALCULATIONS TO MEET LIGHT CODE |
|
| 04/17/2007 | BUILDING - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) 4 WIRE SYSTEM REQUIRED DRYER 2) LIGHT FIXTURES DO NOT MEET OUTDOOR LIGHTING CODE 3) REVERSE POLARITY PORCH RECEPTACLE 4) INSTALL 90 DEGREE ELBOW PORCH PIPE NORTH END 5) TIGHTEN BOLT TO BREAK OFF ANTI-SIPHON HOSE BIB 6) OTHER OUTDOOR RECEPTACLES INOPERATIVE 7) NEED INSULATION CERTIFICATE FROM CONTRACTOR 8) STOPPED INSPECTION |
|
| 04/13/2007 | BUILDING - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* NO ACCESS |