Permit: T06CM03456

Parcel: 12904233B


Addresses:

219 S OLSEN AV


Inspection Status: Approved

Inspection History: PLUMBING - YARD WTR LINE/TEST

Permit Number - T06CM03456

Inspection Description - PLUMBING - YARD WTR LINE/TEST

Inspection Status - Approved

Date Description Inspector Results Comments
11/16/2006 PLUMBING - YARD WTR LINE/TEST Approved IVRS - Inspection :*
11/15/2006 PLUMBING - YARD WTR LINE/TEST Partial Approval IVRS - Inspection :*
- PLAN CALLS FOR NEW 1" METER
- PIPING BELOW GRADE AT RP IS OK TO COVER.
- INSTALL A SECOND UNION ON HORIZONTAL PIPING OR INSTALL UNION ON VERTICAL PIPING TO FACILITATE REMOVAL OF RP.
- INSTALL HB VAC BREAKER
- UNDERGROUND NON-METALLIC PIPING SUPPLY TO FUTURE IRRIGATION ALSO REQUIRES TRACER WIRE AND POTABLE SUPPLY SHALL BE PROTECTED FROM FUTURE IRRIGATION W/A BACKFLOW PREVENTION DEVICE.