Inspection History Details
Inspection Status: Approved
Inspection History: FRAMING
Permit Number - T06CM03435
Inspection Description - FRAMING
Inspection Status - Approved
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 10/27/2006 | FRAMING | Approved | IVRS - Inspection :* | |
| 10/26/2006 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) TIGHTEN ALL RED HEADS 2) ROMEX CONNECTOR EXHAUST FAN LAUNDRY 3) COMPLETELY NAIL FHA STRAPS WHERE PLATES CUT OR OVER BORED 4) PEX NEEDS 12" CLEAR TO CAN LIGHTS KITCHEN 5) REPAIR EXHAUST FLEX BATH 4 6) NAIL STOP VACUUM PIPES 7) NEED CLEANOUT AT LAUNDRY DRAIN |