Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Inspection History Details
Inspection Status: Approved
Inspection History: EXT METAL CLIPS/EXT SHEATHING
Permit Number - T06CM03432
Inspection Description - EXT METAL CLIPS/EXT SHEATHING
Inspection Status - Approved
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 08/16/2006 | EXT METAL CLIPS/EXT SHEATHING | Approved | IVRS - Inspection :* | |
| 08/15/2006 | EXT METAL CLIPS/EXT SHEATHING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) NEED PLANS/PERMIT ON SITE |
|
| 08/10/2006 | EXT METAL CLIPS/EXT SHEATHING | Partial Approval | IVRS - Inspection :* 1) NEED 2 X 2 X 10 BEAM OR 4 X 10 AT PATIO SLIDER 2) NEED 16D AT BEAM HANGER REAR PORCH AHUS 410 |
|
| 08/04/2006 | EXT METAL CLIPS/EXT SHEATHING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) STRAP BEAMS TO LOAD BEARING POSTS 2) NAILS MISSING IN RSP4'S 3) SHEAR WALL STRAP (PER 7/SD2) MUST EXTEND PAST FLOOR TO WALL ABOVE 4) LADDER BLOCKS AND KLEETS MISSING PER 2/SD2 5) LOWER SHEAR PANEL ON EAST WALL MUST BE MIN. 4' WIDE 6) A34 CLIP REQUIRED AT GABLE END BRACING 7) DBL 2 X 6 REQUIRED UNDER INTERIOR 2 X 8 BEAM IN GREAT ROOM 8) PAD REQUIRED UNDER GIRDER POST IN GARAGE 9) INSTALL HANGERS UNDER ENTRY JACKS 10) NAIL ALL SLOPING LEDGERS PER PLAN 11) GABLE END BRACING MISSING AT ENTRY 12) PAD OVER LOAD BEARING HDR IN GREAT ROOM 13) STOPPED INSPECTION |