Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit: T06CM03418

Parcel: 141320200


Addresses:

10352 E YEW PL


Inspection Status: Approved

Inspection History: EXT METAL CLIPS/EXT SHEATHING

Permit Number - T06CM03418

Inspection Description - EXT METAL CLIPS/EXT SHEATHING

Inspection Status - Approved

Date Description Inspector Results Comments
07/21/2006 EXT METAL CLIPS/EXT SHEATHING Approved IVRS - Inspection :*
07/20/2006 EXT METAL CLIPS/EXT SHEATHING Partial Approval IVRS - Inspection :*
1) NAIL FRONT COLUMNS M.A.S. TIES AT BOTTOM PLATE
2) NAIL IN 2" A.B.S. VERTICAL DRAIN REAR WALL
3) MISSING RAT RUNS IN GARAGE
4) USE SHEARWALL SCHEDULE, TO LAYOUT SPACING FOR LTP4'S, SHEARWALL TO TRUSS B/CHORD DETAIL 413