Permit: T06CM03379

Parcel: 141313090

Inspection Status: Approved

Inspection History: FRAMING

Permit Number - T06CM03379

Inspection Description - FRAMING

Inspection Status - Approved

Date Description Inspector Results Comments
01/08/2007 FRAMING Approved IVRS - Inspection :*
01/05/2007 FRAMING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) PRIOR INSPECTION REPAIRS NOT COMPLETE-IEMTS 2 & 10
2) FIRESTOP 2ND FLOOR PENETRATIONS AT BATH TUBS
3) FIRE STOP GARAGE POP OUT
4) BANG PLATES ON LAUNDRY 2" VENT TO ROOF (STAIRWAY SIDE)
5) SHEAR NAILING INCOMPLETE AT ENTRY
6) ITEM 01025 (CLIP/SHEAR) STILL OPEN
7) STAPLE WIRES 8" FROM BOX IN L.R.
8) TIGHTEN RED HEAD ANCHORS
9) SEAL LOOSE FIREBLOCKS AT FAMILY/MASTER SOFFIT
10) FIRE BLOCK AT STAIR LANDING
11) FIRESTOP AT LINE SET THROUGH 2ND FLOOR
01/02/2007 FRAMING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) BANG PLATE 2ND FLOOR LAV DRAIN, 1ST FLOOR POWDER ROOM
2) VERT. BLK SHEAR DRYWALL GARAGE BOTH SIDES
3) BLCK MECH POWDER ROOM
4) LIVING ROOM TO DINING ROOM, 2 PT BEARING TOP PLATE AT TRUSS CHORD
5) NEED TRUSS REPAIR RF2 GARAGE
6) BLK MECH MASTER BATH FAN
7) MISSING SWITCH BOX MASTER BATH
8) BANG PLATE ROMEX TOP PLATE MASTER BATH CLOSET
9) NAIL IN 3" DRAIN MASTER
10) TIGHTEN NUT SHEAR MASTER BATH, NAIL ALL VERT STUDS AT H.D.'S
11) G-3 REQUIRES 4' ON CENTER BLOCKING
12) TRUSS DETAILS FOR ROOF HVAC PLATFORM, TRUSS REPAIR