Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Inspection History Details
Inspection Status: Approved
Inspection History: FRAMING
Permit Number - T06CM03379
Inspection Description - FRAMING
Inspection Status - Approved
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 01/08/2007 | FRAMING | Approved | IVRS - Inspection :* | |
| 01/05/2007 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) PRIOR INSPECTION REPAIRS NOT COMPLETE-IEMTS 2 & 10 2) FIRESTOP 2ND FLOOR PENETRATIONS AT BATH TUBS 3) FIRE STOP GARAGE POP OUT 4) BANG PLATES ON LAUNDRY 2" VENT TO ROOF (STAIRWAY SIDE) 5) SHEAR NAILING INCOMPLETE AT ENTRY 6) ITEM 01025 (CLIP/SHEAR) STILL OPEN 7) STAPLE WIRES 8" FROM BOX IN L.R. 8) TIGHTEN RED HEAD ANCHORS 9) SEAL LOOSE FIREBLOCKS AT FAMILY/MASTER SOFFIT 10) FIRE BLOCK AT STAIR LANDING 11) FIRESTOP AT LINE SET THROUGH 2ND FLOOR |
|
| 01/02/2007 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) BANG PLATE 2ND FLOOR LAV DRAIN, 1ST FLOOR POWDER ROOM 2) VERT. BLK SHEAR DRYWALL GARAGE BOTH SIDES 3) BLCK MECH POWDER ROOM 4) LIVING ROOM TO DINING ROOM, 2 PT BEARING TOP PLATE AT TRUSS CHORD 5) NEED TRUSS REPAIR RF2 GARAGE 6) BLK MECH MASTER BATH FAN 7) MISSING SWITCH BOX MASTER BATH 8) BANG PLATE ROMEX TOP PLATE MASTER BATH CLOSET 9) NAIL IN 3" DRAIN MASTER 10) TIGHTEN NUT SHEAR MASTER BATH, NAIL ALL VERT STUDS AT H.D.'S 11) G-3 REQUIRES 4' ON CENTER BLOCKING 12) TRUSS DETAILS FOR ROOF HVAC PLATFORM, TRUSS REPAIR |