Inspection History Details
Inspection Status: Approved
Inspection History: ELECTRIC - FINAL
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 11/28/2006 | ELECTRIC - FINAL | Approved | IVRS - Inspection :* CONTRACTOR TO BOND CENTER MODULE/ARRAY |
|
| 08/22/2006 | ELECTRIC - FINAL | Denied | IVRS - Inspection : The wiring is not complete or does not comply with code.| 245* 1. GROUNDING CONNECTIONS TO PANELS ARE STILL LOOSE IF SCREWS ARE STRIPPED THEY WILL NEED TO BE RE-TAPPED OR USE LUG WITH NUT AND BOLT. ALSO, WRAP EQUIPMENT GROUND 2/3RDS AROUND SCREW THEN PINCH AND TIGHTEN CONDUCTOR - DO NOT OVERLAP EQUIPMENT GROUND AROUND GROUND SCREW. WILL NEED TO PAY REINSPECTION FEE BEFORE FINAL APPROVAL. |
|
| 08/16/2006 | ELECTRIC - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* EQUIP. GROUNDING CONNECTIONS AT PANELS ON ROOF ARE LOOSE. |