Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit: T06CM03291

Parcel: 126080290


Addresses:

4106 E 5TH ST

Inspection Status: Approved

Inspection History: EXT METAL CLIPS/EXT SHEATHING

Date Description Inspector Results Comments
08/16/2006 EXT METAL CLIPS/EXT SHEATHING Approved IVRS - Inspection :*
08/10/2006 EXT METAL CLIPS/EXT SHEATHING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) COMPLY WITH DETAIL 8/S02 H2.5 EACH JOIST
2) COMPLY WITH DETAIL 6/S02 AT EXISTING BLOCK AND A35'S
3) BLOCK AND NAIL SHEARWALLS AT JOINTS WHERE NEEDED