Permit: T06CM03286

Parcel: 106051300

Inspection Status: Approved

Inspection History: ROOF NAILING

Date Description Inspector Results Comments
07/21/2006 ROOF NAILING Approved IVRS - Inspection :*
07/03/2006 ROOF NAILING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) INSTALL STRAPS EXTERIOR BOTTOM PLATES AT PLUMBING CUT OUTS
2) HOLDOWN NAILS MISSING STUD PENETRATION
3) BLOCKING MISSING TOP AND BOTTOM OF LEDGERS
4) SIMPSON H2.5'S MISSING LEDGER TO STUDS
5) NEED LADDER TO INSPECT ROOF
6) NEED I-JOIST SPECS
7) SOLID BLOCKING AND VENTING MISSING EXTERIOR WALLS I-JOIST AT BEARING
8) 12" X 4" HOLES FOR VENTING OUT TO SMALL
9) UNABLE VERIFY LPI JOISTS-APPEARS BCI ? (ANOTHER MANUFACTURER)
10) STOPPED INSPECTION