Permit: T06CM03250

Parcel: 116154780


Addresses:

318 N HASMAN DR

Inspection Status: Approved

Inspection History: PLUMBING - INTERMEDIATE

Date Description Inspector Results Comments
12/05/2007 PLUMBING - INTERMEDIATE Approved IVRS - Inspection :*
05/18/2007 PLUMBING - INTERMEDIATE Not ready for Inspection IVRS - Inspection :*
SCREW CLOSET FLANGE TO FLOOR
04/25/2007 PLUMBING - INTERMEDIATE Partial Approval IVRS - Inspection :*
1. OK TO COVER ALL AREAS
2. NEED TO SEE 1ST FLOOR CLOSET FLANGES
3. REMEMBER -- TRAP ARMS ARE TO BE INSTALLED AT 1/4" PER FOOT
04/18/2007 PLUMBING - INTERMEDIATE Not ready for Inspection IVRS - Inspection :*
1. A DRAIN MAY NOT DUMP INTO A VENT
2. SUPPORT ABS AT EACH CHANGE OF DIRECTION OR ELEVATION, AND AT THE END OF BRANCHES, THEN NO MORE THAN FOUR FEET BETWEEN HANGERS.
3. HORIZONTAL X HORIZONTAL CHANGE OF DIRECTION TO BE A SWEEP
4. NEED TO SEE FIRST FLOOR CLOSET FLANGES
04/02/2007 PLUMBING - INTERMEDIATE Not ready for Inspection IVRS - Inspection :*
REPAIR LEAKS