Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - INTERMEDIATE
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 12/05/2007 | PLUMBING - INTERMEDIATE | Approved | IVRS - Inspection :* | |
| 05/18/2007 | PLUMBING - INTERMEDIATE | Not ready for Inspection | IVRS - Inspection :* SCREW CLOSET FLANGE TO FLOOR |
|
| 04/25/2007 | PLUMBING - INTERMEDIATE | Partial Approval | IVRS - Inspection :* 1. OK TO COVER ALL AREAS 2. NEED TO SEE 1ST FLOOR CLOSET FLANGES 3. REMEMBER -- TRAP ARMS ARE TO BE INSTALLED AT 1/4" PER FOOT |
|
| 04/18/2007 | PLUMBING - INTERMEDIATE | Not ready for Inspection | IVRS - Inspection :* 1. A DRAIN MAY NOT DUMP INTO A VENT 2. SUPPORT ABS AT EACH CHANGE OF DIRECTION OR ELEVATION, AND AT THE END OF BRANCHES, THEN NO MORE THAN FOUR FEET BETWEEN HANGERS. 3. HORIZONTAL X HORIZONTAL CHANGE OF DIRECTION TO BE A SWEEP 4. NEED TO SEE FIRST FLOOR CLOSET FLANGES |
|
| 04/02/2007 | PLUMBING - INTERMEDIATE | Not ready for Inspection | IVRS - Inspection :* REPAIR LEAKS |