Inspection History Details
Inspection Status: Approved
Inspection History: EXT METAL CLIPS/EXT SHEATHING
Permit Number - T06CM03238
Inspection Description - EXT METAL CLIPS/EXT SHEATHING
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
11/17/2006 | EXT METAL CLIPS/EXT SHEATHING | Approved | IVRS - Inspection :* | |
11/15/2006 | EXT METAL CLIPS/EXT SHEATHING | Partial Approval | IVRS - Inspection :* 1) PRIOR INSPECTION ASKED FOR VERIFICATION ABOUTH NOTCHING 1A1 TRUSS 2) TAPE JOINT AROUND BAY WINDOW 3) NOT ENOUGH PRESSURE TO TEST |
|
10/09/2006 | EXT METAL CLIPS/EXT SHEATHING | Partial Approval | IVRS - Inspection :* 1) OK TO LATHE 2) NEED GUSSET PLATE GARAGE TRUSS 1B3 3) QUEST CAN 1A1 TRUSS BE NOTCHED AT TOP CHORD OVER GABLE |
|
10/05/2006 | EXT METAL CLIPS/EXT SHEATHING | Not ready for Inspection | IVRS - Inspection :* ITEMS 1 - 2 - 3 NOT RESOLVED |
|
10/02/2006 | EXT METAL CLIPS/EXT SHEATHING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) 1ST TRUSS WEST OF GARAGE GIRDER MISSING A GUSSET PLATE 2) TRUSS OVER REAR BAY WINDOW IS NOTCHED AT TOP CHORD SHOULDN'T BE (REF. TRUSS MANUFACTURER 3) WRONG SIZE NAILS IN P.A.'S MINIMUM .0148 16D SINKER 4) NEED RETRO P.A. AT GARAGE FRONT |