Inspection History Details
Inspection Status: Approved
Inspection History: FRAMING
Permit Number - T06CM03236
Inspection Description - FRAMING
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
10/26/2006 | FRAMING | Approved | IVRS - Inspection :* | |
10/24/2006 | FRAMING | Partial Approval | IVRS - Inspection :* 1. DIVERTER STUD NOTCHED TOO DEEP 2. WRONG NAILS IN H.D FRONT BATH & BEDROOM 3. MISSING COVER PLATE CAN LIGHT/HALL 4. NEED PAPERWORK FOR APPROVING NOTCHED TOP - CHORD FOR TRUSS ACROSS BAY WINDOW. 5. INSTALL 2X8 FROM PEAK DOWN TO OUTSIDE BEARING TO REPAIR TRUSS NOTCHED FOR OUT RIGGERS, REPAIR PER DETAIL. |