Permit: T06CM03205

Parcel: 141330440


Addresses:

8415 S EGYPTIAN DR


Inspection Status: Approved

Inspection History: FRAMING

Permit Number - T06CM03205

Inspection Description - FRAMING

Inspection Status - Approved

Date Description Inspector Results Comments
04/20/2007 FRAMING Approved IVRS - Inspection :*
03/13/2007 FRAMING Not ready for Inspection IVRS - Inspection :*
1) CANCELLED PER SUPER
03/02/2007 FRAMING Partial Approval IVRS - Inspection :*
1) CONCRETE SLAB WAS CUT TO MAKE CORRECTIONS TO A LEAK IN 3" ABS. IT IS OK TO INSULATE AND DRYWALL AT THIS TIME. I WILL APPROVE FRAMING WHEN FINAL POUR OF CEMENT AT CUT-OUT IS FINISHED. WAITING ON PAPERWORK
02/02/2007 FRAMING Partial Approval IVRS - Inspection :*
01/24/2007 FRAMING Cancelled IVRS - RI canceled
01/18/2007 FRAMING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) REMOVE REBAR AT GARAGE
2) FIRESTOP AT CHASE OPENINGS
3) NEED NAILS IN JACK TRUSS HANGER 2ND FLOOR
4) SHIM ALL HEADERS EXT WALL
5) PEX LINE KITCHEN CEILING NEEDS TO BE ABOVE BLOCKING
6) PEX LINE IN DINING ROOM TO CLOSE TO CAN LIGHT
7) PSI GAS PRESSURE
8) BLOCK DUCT BOOT 3 SIDES DOWNSTAIRS BATH CORRECTED
01/10/2007 FRAMING Not ready for Inspection IVRS - Inspection :*
1) CANCELLED PER SUPER-NOT READY