Permit: T06CM03203

Parcel: 141330420


Addresses:

8431 S EGYPTIAN DR


Inspection Status: Approved

Inspection History: ELECTRIC - INTERMEDIATE

Permit Number - T06CM03203

Inspection Description - ELECTRIC - INTERMEDIATE

Inspection Status - Approved

Date Description Inspector Results Comments
01/18/2007 ELECTRIC - INTERMEDIATE Approved IVRS - Inspection :*
01/09/2007 ELECTRIC - INTERMEDIATE Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) RISER NOT CONNECTING TO PANEL BOX
2) ELECTRICAL PANEL WILL NEED GROUND RODS FOR UFER
3) VALVE IS LEAKING AT OUTSIDE MAIN LINE
4) MISSING ANTI-SIPHON ON HOSE BIB
5) NO INSULATION BEHIND SHOWER ENCLOSURE MASTER BATH
6) SECURE PEX LINE TO OUTSIDE WATER MASTER BATH
7) 2ND ? A/C DRAIN LINE, NEEDS TO TERMINATE OVER A WINDOW
8) MISSING WINDOW
9) NAILING ON SHEARTRANSFER NOT PER 5/D3
10) NEED FIRESTOP AT POP OUTS FRONT BEDROOM
11) CUT REBAR UFER IF NOT GOING TO BE USED FRONT BEDROOM
12) SHIM HEADERS ON EXT. WALL