Permit: T06CM03200

Parcel: 141330400


Addresses:

8447 S EGYPTIAN DR


Inspection Status: Approved

Inspection History: FRAMING

Permit Number - T06CM03200

Inspection Description - FRAMING

Inspection Status - Approved

Date Description Inspector Results Comments
02/08/2007 FRAMING Approved IVRS - Inspection :*
02/07/2007 FRAMING Partial Approval IVRS - Inspection :*
1) ALL ITEMS HAVE BEEN CORRECTED
2) SINCE ALL ELECTRICAL WIRING WAS CUT OUT AND NEEDS TO BE REPLACED-I WILL NEED TO REINSPECT TO SIGN OFF ON FINAL FRAME
02/02/2007 FRAMING Cancelled IVRS - RI canceled
01/19/2007 FRAMING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) ITEM #3
2) ITEM #4 SHEARWALL AT DEN NOT CORRECTED
01/18/2007 FRAMING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) ITEMS 1, 3, 4 AND 6 NEED TO BE CORRECTED
01/09/2007 FRAMING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) DBL STUD AT DBL GIRDER IN GARAGE NEEDS TO BE UNDERNEATH DBL GIRDER
2) NO INSULATION BEHIND TUB ENCLOSURE EXT. WALL AND MASTER BATH ALSO
3) SHOWER TUB BACKING MASTER BEDROOM
4) SHEAR TRANSFER NAILING ON 2 X 12 NOT PER 5/D3
5) MISSING RISER TO PANEL BOX
6) UFER CABLE LOOSE ON CLAMP
7) PLUG LEAKING AT OUTSIDE HOUSE BIB
8) ANTI-SIPHON MISSING
9) STAPLE IN OUTSIDE WATER LINE (PEX)