| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 11/02/2006 | FRAMING | Approved | IVRS - Inspection :* | |
| 10/31/2006 | FRAMING | Partial Approval | IVRS - Inspection :* 1) MISSING STRAPS GARAGE DOOR OPENING 13/SD2 2) GARAGE SHEAR WALL NEEDS NAILS IN OSB BOARD BETWEEN TRUSSES 3) EXIT 2 X 6 WALL NORTH SIDE GUEST BEDROOM-NEEDS NAILING BOTTOM PLATE |