Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - FINAL
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 01/03/2007 | PLUMBING - FINAL | Approved | IVRS - Inspection :* | |
| 12/21/2006 | PLUMBING - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* REFEE THERE ARE 10 VENTS ON THIS BUILDING THAT ARE NOT PROTECTED FROM UV RAYS. THIS IS THE 6TH FINAL INSPECTION YOU ARE BEING ASSESSED A REFEE BECAUSE YOU HAVE NOT COMPLETED ALL OF THE REQUESTED CORRECTIONS. NO FINAL INSPECTIONS WILL BE PERFORMED UNTIL FEE IS PAID. |
|
| 12/11/2006 | PLUMBING - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1. WEST TOILET ROOM C O HAS A PLASTIC PLUG WITH A HOLE DRILLED IN IT, THE COVER HAS FALLEN OFF. PROVIDE THE PROPER FITTING FOR THIS APPLICATION. 2. THE WH EXPANSION TANK IS UNDER STRAIN FROM PLUMBERS TAPE AND IS TOUCHING A COPPER WATER LINE. PTAPE IS NOT AN APPROVED HANGER. SUPPORT EXPANSION TANK WITH AN APPROVED PIPE SUPPORT AND DO NOT STRAIN PIPING. 3. OVERHEAD HORIZONTAL COPPER UNDER 2" REQUIRES SUPPORT AT 6' MAX. INSTALL PIPE SUPPORTS ON 1/2" HORIZONTAL COPPER ABOVE CEILING. 4. UPC REQUIRES THAT EXPOSED PLASTIC VENT TERMINATIONS BE PROTECTED FROM UV RAYS W/LATEX PAINT. PREVIOUSLY LADDER ACCESS TO ROOF HAS NOT BEEN PROVIDED. IT WAS ASSUMED THAT YOUR VENT TERMINATIONS WERE PROTECTED AS REQUIRED. IT HAS COME TO MY ATTENTION THAT THEY WERE NOT. ALL PLASTIC VENTS ON THIS BUILDING WILL BE PROTECTED BEFORE I WILL FINAL ANY REMAINING PERMITS! |
|
| 11/29/2006 | PLUMBING - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* PAINT ALL EXPOSED PLASTIC VENT PIPING ON ROOF DO NOT DRILL OR TAP PLASTIC CO PLUGS ALSO MAKE PLUGS GAS TIGHT W/THE USE OF APPROVED THREAD SEALANT. RESTROOMS ARE CONSIDERED PUBLIC USE PROVIDE DIELECTRIC PROTECTION BETWEEN WH AND COPPER PIPING. SUPPORT EXP. TANK CORRECT ELECTRICAL CONNECTION HAVE ELECTRICAL INSPECTOR CHECK IT. PROVIDE DRAIN ON PAN ABOVE CEILING. |
|
| 11/21/2006 | PLUMBING - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1. CLEAN OUT PLUGS 2. PROVIDE LADDER ACCESS FOR WH INSPECTION 3. PUBLIC USE LAVATORIES REQUIRE MIXING VALVE/TEMPERATURE LIMITING DEVICE OTHER THAN WH CONTROL. |
|
| 11/08/2006 | PLUMBING - FINAL | Not ready for Inspection | IVRS - Inspection :* 1) CAP OPEN SEWER PIPING IN OCCUPIED BLDG |
|
| 08/24/2006 | PLUMBING - FINAL | Not ready for Inspection | IVRS - Inspection :* | |
| 08/18/2006 | PLUMBING - FINAL | Not ready for Inspection | IVRS - Inspection :* |