Permit: T06CM03158

Parcel: 108252340

Inspection Status: Approved

Inspection History: ELECTRIC - FINAL

Permit Number - T06CM03158

Inspection Description - ELECTRIC - FINAL

Inspection Status - Approved

Date Description Inspector Results Comments
06/19/2007 ELECTRIC - FINAL Approved IVRS - Inspection :*
06/18/2007 ELECTRIC - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
1. AC DISCONNECTS TO HAVE PROPER FRONT WORKING CLEARANCE - 30" WIDE, 36" DEEP --- NEC 110.26
2. USE PROPER SIZED STRAPS FOR FLEX DISCONNECTS
TO AC'S - NEC 110.3B
3. IDENTIFY AC 1 DATA PLATE
4. PANEL DIRECTORY NOT CORRECT - NEC 408.4
5. DISHWASHER/ELEVATOR NOT COMPLETE
6. GARAGE RECEPTACLE TO BE GFI PROTECTED