Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
11/14/2006 | ROOF NAILING | Approved | IVRS - Inspection :* | |
11/09/2006 | ROOF NAILING | Partial Approval | IVRS - Inspection :* 1) SEE PRIOR NOTES 2) NEED TRUSS CALC'S 3) ADD 2 X 6 TO TOP PLATE WHERE DRYER MOVED 4) SHIM SPACES IN BLOCKS IN DINING WALL 5) TIGHTEN RED HEADS 6) REPAIR AT BATH TUBS 7) COMPLETE COLUMN AT BACK PORCH 8) NO GAS BOND 9) RE-ATTACH ? IN LAUNDRY AND RECEPTACLE IN HALL 10) ADD RECEPTACLE L/R SIDE PENINSULA 1F COUNTER DOES NOT EXTEND OVER 6" 11) HCS AND YARD LINE NEED TRACER WIRES |
|
11/08/2006 | ROOF NAILING | Not ready for Inspection | IVRS - Inspection :* | |
09/14/2006 | ROOF NAILING | Partial Approval | IVRS - Inspection :* 1) NAILING OK 2) NEED TRUSS PLANS FOR ELEVATION "B" TO CHECK INTERIOR RAT RUNS AND CLIPS AT FRAME INSPECTION 3) OK TO ROOF |