Date Description Inspector Results Comments
11/14/2006 ROOF NAILING Approved IVRS - Inspection :*
11/09/2006 ROOF NAILING Partial Approval IVRS - Inspection :*
1) SEE PRIOR NOTES
2) NEED TRUSS CALC'S
3) ADD 2 X 6 TO TOP PLATE WHERE DRYER MOVED
4) SHIM SPACES IN BLOCKS IN DINING WALL
5) TIGHTEN RED HEADS
6) REPAIR AT BATH TUBS
7) COMPLETE COLUMN AT BACK PORCH
8) NO GAS BOND
9) RE-ATTACH ? IN LAUNDRY AND RECEPTACLE IN HALL
10) ADD RECEPTACLE L/R SIDE PENINSULA 1F COUNTER DOES NOT EXTEND OVER 6"
11) HCS AND YARD LINE NEED TRACER WIRES
11/08/2006 ROOF NAILING Not ready for Inspection IVRS - Inspection :*
09/14/2006 ROOF NAILING Partial Approval IVRS - Inspection :*
1) NAILING OK
2) NEED TRUSS PLANS FOR ELEVATION "B" TO CHECK INTERIOR RAT RUNS AND CLIPS AT FRAME INSPECTION