Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit: T06CM03141

Parcel: 141320320


Addresses:

6057 S WYCH ELM PL


Inspection Status: Approved

Inspection History: EXT METAL CLIPS/EXT SHEATHING

Permit Number - T06CM03141

Inspection Description - EXT METAL CLIPS/EXT SHEATHING

Inspection Status - Approved

Date Description Inspector Results Comments
10/03/2006 EXT METAL CLIPS/EXT SHEATHING Approved IVRS - Inspection :*
09/28/2006 EXT METAL CLIPS/EXT SHEATHING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) NAIL OFF 5 SHEAR 3" ON CENTER
2) STAPLES MISSED RAFTER 1 SEAM
3) SOUTH SIDE 2ND FULL SHEET FROM WEST
4) 1ST FULL SHEET FROM PEAK
5) ADD STUD MIDDLE WINDOW SOUTH SIDE UNDER BREAK IN TOP PLATE
09/26/2006 EXT METAL CLIPS/EXT SHEATHING Denied IVRS - Inspection :
See detailed listing on site.| 999*