Inspection Status: Approved
Inspection History: EXT METAL CLIPS/EXT SHEATHING
Permit Number - T06CM03140
Inspection Description - EXT METAL CLIPS/EXT SHEATHING
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
11/21/2006 | EXT METAL CLIPS/EXT SHEATHING | Approved | IVRS - Inspection :* | |
11/17/2006 | EXT METAL CLIPS/EXT SHEATHING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) STILL MISSING HOLDOWN SHEARWALL BETWEEN BEDROOMS 2) STUCCO MESH NOT COMPLETE |
|
11/15/2006 | EXT METAL CLIPS/EXT SHEATHING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) NO RETRO FOR STHD14 GARAGE S. SIDE 2) NEED TRUSS CALC'S TO SEE TRUSS WHERE NOTCHED AT 3) MISSING WIND BRACE N. SIDE 4) DENIED UNTIL ISSUES WITH TRUSSES AND H.D. CAN BE RESOLVED |
|
10/10/2006 | EXT METAL CLIPS/EXT SHEATHING | Partial Approval | IVRS - Inspection :* 1) OK TO WRAP 2) RETRO AT GARAGE S. SIDE CLOSET TO DOOR JAMB 3) REAR SHEAR AT TUB VENT 4) ALL ITEMS 1-8 NOT DONE |
|
10/02/2006 | EXT METAL CLIPS/EXT SHEATHING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) BROKEN WEB IN TRUSS ABOVE LAUNDRY ROOM 2) NEED TOTAL TWO WIND BRACES S. WALL 3) LEAVE TRUSS DRAWINGS 4) STHD14 AT S. SIDE OF GARAGE, EMBEDMENT EXPOSED NEED RETRO H.D. 5) MISSING WIND BRACE NORTH SIDE 6) X BRACE TRUSSES FRONT BACK AND 25' ON CENTER 7) REAR TRUSS NOTCHED ? OUT RIGGERS CHECK WITH TRUSS MANUFACTURER, NOT TO BE NOTCHED IN AREAS NO OUT RIGGERS 8) SEE REAR P.A. AT ABS ? |