Permit: T06CM03140

Parcel: 141320270


Addresses:

6064 S WYCH ELM PL


Inspection Status: Approved

Inspection History: EXT METAL CLIPS/EXT SHEATHING

Permit Number - T06CM03140

Inspection Description - EXT METAL CLIPS/EXT SHEATHING

Inspection Status - Approved

Date Description Inspector Results Comments
11/21/2006 EXT METAL CLIPS/EXT SHEATHING Approved IVRS - Inspection :*
11/17/2006 EXT METAL CLIPS/EXT SHEATHING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) STILL MISSING HOLDOWN SHEARWALL BETWEEN BEDROOMS
2) STUCCO MESH NOT COMPLETE
11/15/2006 EXT METAL CLIPS/EXT SHEATHING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) NO RETRO FOR STHD14 GARAGE S. SIDE
2) NEED TRUSS CALC'S TO SEE TRUSS WHERE NOTCHED AT
3) MISSING WIND BRACE N. SIDE
4) DENIED UNTIL ISSUES WITH TRUSSES AND H.D. CAN BE RESOLVED
10/10/2006 EXT METAL CLIPS/EXT SHEATHING Partial Approval IVRS - Inspection :*
1) OK TO WRAP
2) RETRO AT GARAGE S. SIDE CLOSET TO DOOR JAMB
3) REAR SHEAR AT TUB VENT
4) ALL ITEMS 1-8 NOT DONE
10/02/2006 EXT METAL CLIPS/EXT SHEATHING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) BROKEN WEB IN TRUSS ABOVE LAUNDRY ROOM
2) NEED TOTAL TWO WIND BRACES S. WALL
3) LEAVE TRUSS DRAWINGS
4) STHD14 AT S. SIDE OF GARAGE, EMBEDMENT EXPOSED NEED RETRO H.D.
5) MISSING WIND BRACE NORTH SIDE
6) X BRACE TRUSSES FRONT BACK AND 25' ON CENTER
7) REAR TRUSS NOTCHED ? OUT RIGGERS CHECK WITH TRUSS MANUFACTURER, NOT TO BE NOTCHED IN AREAS NO OUT RIGGERS
8) SEE REAR P.A. AT ABS ?