Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit: T06CM03121

Parcel: 13331159Y


Addresses:

8740 E BROADWAY BL


Inspection Status: Partial Approval

Inspection History: PLUMBING - PROGRESS

Permit Number - T06CM03121

Inspection Description - PLUMBING - PROGRESS

Inspection Status - Partial Approval

Date Description Inspector Results Comments
10/11/2006 PLUMBING - PROGRESS Partial Approval IVRS - Inspection :*
DELTA 2 DATED 7/12/06 IS SERVING AS REDLINE DRAWING WITH ORIGINAL PLAN DATED 6/26/06 STANTEC.
UNDERGROUND IN DELI WATER TEST THRU ROOF E WF FS-2,
(2) STUBS (1) FOR 3-COMP SINK (1) FOR BACK TO LAV TO BE CONTINUED AND JANITOR SINK WITH WATER PIPING FOR SAME INTERMEDIATE PARTIAL APPROVAL. UNDERGROUND WASTE & VENT TO EXISTING IN DELI CENTER OK
3" FLOOR SINK COMBO WASTE & VENT TO EXISTING WATER TEST OK AISLE #14