Permit: T06CM03121

Parcel: 13331159Y


Addresses:

8740 E BROADWAY BL


Inspection Status: Partial Approval

Inspection History: PLUMBING - INTERMEDIATE

Permit Number - T06CM03121

Inspection Description - PLUMBING - INTERMEDIATE

Inspection Status - Partial Approval

Date Description Inspector Results Comments
12/12/2006 PLUMBING - INTERMEDIATE Partial Approval IVRS - Inspection :*
WATER & VENT PIPING FOR RELOCATED 3-COMP SINK IN
MEAT & HAND SINK AREA OK
SHALL MAKE FINAL CONNECTIONS ON THIS SINK ASAP
FROM TEMPORARY HOOK UP.
11/01/2006 PLUMBING - INTERMEDIATE Partial Approval IVRS - Inspection :*
WASTE & VENT & WATER IN BUTCHER AREA OK
100 PSI TEST FLORAL HELIUM LINE OK
WASTE & VENT & WATER IN FLORAL OK
WASTE & VENT & WATER IN DELI OK
09/27/2006 PLUMBING - INTERMEDIATE Partial Approval IVRS - Inspection :*
WATER PIPING OK EXCEPT FOR WALL HUNG LAV BAKERY AREA
(OVERHEAD) SHALL BE TIED IN.
09/20/2006 PLUMBING - INTERMEDIATE Not ready for Inspection IVRS - Inspection :*
SEE NOTES FROM 8/25/06 INSPECTIN AND COMPLY AT STARBUCKS!
08/25/2006 PLUMBING - INTERMEDIATE Partial Approval IVRS - Inspection :*
STARBUCKS TO HAVE CORRECT LABELING FOR WASH, RINSE, SANITIZE AT 3-COMP SINK OR CORRECT DRAINAGE.
ESPRESSO MACHINE TO HAVE GRAVITY DRAIN FROM LATCH PANS.
08/17/2006 PLUMBING - INTERMEDIATE Partial Approval IVRS - Inspection :*
08/16/2006 PLUMBING - INTERMEDIATE Partial Approval IVRS - Inspection :*
WATER TEST VENTS FOR STARBUCKS OK
1. SHALL PROVIDE WRAPS THRU CONCRETE AT FLOOR LEVEL ALL PIPING.
2. SHALL SUPPORT OVERHEAD PLASTIC PIPING AT 4' INTERVALS.
3. PROVIDE BACKFLOW PROTECTION FOR ICE MACHINE & COFFEE BREWER IF PROOF OF 1" AIR GAP CANNOT BE MADE.
4. PROVIDE BACKFLOW CERTIFICATION FOR IN HOUSE DEVICES
5. PROVIDE 1" AIR GAP AT FLOOR SINKS FOR INDIRECT DRAINS
6. INDIRECT DRAINS TO GRAVITY DRAIN AND BE RIDGID PIPING