Inspection History Details
Inspection Status: Partial Approval
Inspection History: PLUMBING - ROUGH, SOIL
Permit Number - T06CM03121
Inspection Description - PLUMBING - ROUGH, SOIL
Inspection Status - Partial Approval
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
12/01/2006 | PLUMBING - ROUGH, SOIL | Partial Approval | IVRS - Inspection :* WATER TEST UNDERGROUND WASTE & VENT WITHIN WALL VENT TO POINT OF CONNECTION TO EXISTING IN MEAT/SEAFOOD PROP PER 8 1/2 X 11 SERVING AS REDLINE DATED 11/21/06 OWNER CHANGES REVISION #1 FOR FLOOR SINK & RELOCATED 3-COMP SINK |
|
11/28/2006 | PLUMBING - ROUGH, SOIL | Partial Approval | IVRS - Inspection :* WATER TEST WASTE & VENT FLOOR SINK CHEESE CASE OK |
|
11/01/2006 | PLUMBING - ROUGH, SOIL | Partial Approval | IVRS - Inspection :* PERM CAPS OF FLOOR SINKS (5) WATER TEST WASTE & VENT HAND SINK BUTCHER AREA THRU ROCK OK |
|
10/26/2006 | PLUMBING - ROUGH, SOIL | Partial Approval | IVRS - Inspection :* WASTE & VENT THRU ROOF (1) BACK TO BACK LAVS (2) FLOOR SINKS WITH VENTS IN DELI OK COMBINATION WASTE & VENT AT PRODUCE 2 FLOOR SINKS OK WATER TEST 2" FLOOR SINK IN PRODUCE AREA WATER TEST OK |
|
10/23/2006 | PLUMBING - ROUGH, SOIL | Partial Approval | IVRS - Inspection :* - WATER TEST FOR UNDERGROUND WITH LOOP VENT THRU ROOF INCLUDING ADDITION OF 3" FS FOR DRAINAGE AT FLORAL OK - FS TO BE ON CITY APPROVED REVISED PLAN - HELIUM & WATER ALSO LOOPED UNDER SLAB OK - 3" FLOOR SINK FOR BUTCHER DISPLAY CASE UNDERGROUND OK |
|
09/27/2006 | PLUMBING - ROUGH, SOIL | Partial Approval | IVRS - Inspection :* BAKERY AREA WATER TEST UNDERGROUND WASTE & VENT THRU ROOF OK. DELI - PIPING SHALL BE INSTALLED PER APPROVED PLAN, OR PROVIDE REVISED CITY APPROVED PLAN. 1. CONTRACTOR TO TIE TOGETHER VENTS TO EXISTING. |
|
09/12/2006 | PLUMBING - ROUGH, SOIL | Partial Approval | IVRS - Inspection :* 1. RED LINE DRAWING FOR 3" VENT THRU FLOOR NORTH OF WHERE DRAWING SHOW. 2. PARTIAL APPROVAL FOR COMBO WASTE & VENT FLOOR DRAINS #13 ROW |
|
07/31/2006 | PLUMBING - ROUGH, SOIL | Partial Approval | IVRS - Inspection :* STARBUCKS UNDERGROUND WATER TEST PER 8 1/2 X 11'S FROM JAMES STEWART PALMER DATED 7/28/06 SERVING AS REDLINES, THIS AND ANY OTHER CHANGES SHALL REQUIRE REVISED CITY APPROVED PLAN. |
|
07/28/2006 | PLUMBING - ROUGH, SOIL | Not ready for Inspection | IVRS - Inspection :* PLAN APPEARS TO BE APPROVED IN ERROR 1. HAND SINKS SHALL BE CONNECTED TO DIRECT DRAINAGE CONNECTION. 2. 3-COMPARTMENT SINK SHALL HAVE DIRECT DRAINAGE CONNECTION FOR WASH & RINSE COMPARTMENTS AND SEPARATE INDIRECT DRAINAGE FOR SANITIZE COMPARTMENT. |