Permit: T06CM03121

Parcel: 13331159Y


Addresses:

8740 E BROADWAY BL

Inspection Status: Partial Approval

Inspection History: PLUMBING - ROUGH, SOIL

Date Description Inspector Results Comments
12/01/2006 PLUMBING - ROUGH, SOIL Partial Approval IVRS - Inspection :*
WATER TEST UNDERGROUND WASTE & VENT WITHIN WALL VENT TO POINT OF CONNECTION TO EXISTING IN MEAT/SEAFOOD PROP PER 8 1/2 X 11 SERVING AS REDLINE DATED 11/21/06 OWNER CHANGES REVISION #1 FOR FLOOR SINK & RELOCATED 3-COMP SINK
11/28/2006 PLUMBING - ROUGH, SOIL Partial Approval IVRS - Inspection :*
WATER TEST WASTE & VENT FLOOR SINK CHEESE CASE OK
11/01/2006 PLUMBING - ROUGH, SOIL Partial Approval IVRS - Inspection :*
PERM CAPS OF FLOOR SINKS (5) WATER TEST WASTE & VENT HAND SINK BUTCHER AREA THRU ROCK OK
10/26/2006 PLUMBING - ROUGH, SOIL Partial Approval IVRS - Inspection :*
WASTE & VENT THRU ROOF
(1) BACK TO BACK LAVS
(2) FLOOR SINKS WITH VENTS IN DELI OK

COMBINATION WASTE & VENT AT PRODUCE 2 FLOOR SINKS
OK WATER TEST
2" FLOOR SINK IN PRODUCE AREA WATER TEST OK
10/23/2006 PLUMBING - ROUGH, SOIL Partial Approval IVRS - Inspection :*
- WATER TEST FOR UNDERGROUND WITH LOOP VENT THRU ROOF INCLUDING ADDITION OF 3" FS FOR DRAINAGE AT FLORAL OK
- FS TO BE ON CITY APPROVED REVISED PLAN
- HELIUM & WATER ALSO LOOPED UNDER SLAB OK
- 3" FLOOR SINK FOR BUTCHER DISPLAY CASE UNDERGROUND OK
09/27/2006 PLUMBING - ROUGH, SOIL Partial Approval IVRS - Inspection :*
BAKERY AREA WATER TEST UNDERGROUND WASTE & VENT THRU ROOF OK.

DELI - PIPING SHALL BE INSTALLED PER APPROVED PLAN, OR PROVIDE REVISED CITY APPROVED PLAN.
1. CONTRACTOR TO TIE TOGETHER VENTS TO EXISTING.
09/12/2006 PLUMBING - ROUGH, SOIL Partial Approval IVRS - Inspection :*
1. RED LINE DRAWING FOR 3" VENT THRU FLOOR NORTH OF WHERE DRAWING SHOW.
2. PARTIAL APPROVAL FOR COMBO WASTE & VENT FLOOR DRAINS #13 ROW
07/31/2006 PLUMBING - ROUGH, SOIL Partial Approval IVRS - Inspection :*
STARBUCKS UNDERGROUND WATER TEST PER 8 1/2 X 11'S FROM JAMES STEWART PALMER DATED 7/28/06 SERVING AS REDLINES, THIS AND ANY OTHER CHANGES SHALL REQUIRE REVISED CITY APPROVED PLAN.
07/28/2006 PLUMBING - ROUGH, SOIL Not ready for Inspection IVRS - Inspection :*
PLAN APPEARS TO BE APPROVED IN ERROR
1. HAND SINKS SHALL BE CONNECTED TO DIRECT DRAINAGE CONNECTION.
2. 3-COMPARTMENT SINK SHALL HAVE DIRECT DRAINAGE CONNECTION FOR WASH & RINSE COMPARTMENTS AND SEPARATE INDIRECT DRAINAGE FOR SANITIZE COMPARTMENT.