Permit: T06CM03117

Parcel: 12507443A


Addresses:

2715 E 7TH ST

Inspection Status: Approved

Inspection History: BUILDING - FINAL

Date Description Inspector Results Comments
05/23/2007 BUILDING - FINAL Approved IVRS - Inspection :*
05/22/2007 BUILDING - FINAL Partial Approval IVRS - Inspection :*
1) NEED STUCCO AND INSULATION CERTS
2) NEED SCREEN OR COVER HOLES ON SIDE OF BLDG
3) W/HEATER CANNOT OPEN INTO LIVING SPACE
05/16/2007 BUILDING - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) ENTRANCE STOOP NEEDS TO BE 3' WIDE AND LENGTH OF DOOR OPENING AT DBL DOORS AND AT KITCHEN
2) OPEN GROUND ON OUTLET LAUNDRY ROOM
3) W/HEATER NEEDS SHEET METAL ON BOTTOM OF STAND
4) INSTALL 3 METAL SCREWS ON DBL B-VENT CONNECTION
5) COMBUSTION AIR NOT TO CODE
6) TRAP NOT INSTALLED ON A/C UNIT
7) A/C DISCONNECT NEEDS TO BE RELOCATED
8) LOWER CLEANOUT TO GRADE