Inspection History Details
Inspection Status: Approved
Inspection History: BUILDING - FINAL
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 05/23/2007 | BUILDING - FINAL | Approved | IVRS - Inspection :* | |
| 05/22/2007 | BUILDING - FINAL | Partial Approval | IVRS - Inspection :* 1) NEED STUCCO AND INSULATION CERTS 2) NEED SCREEN OR COVER HOLES ON SIDE OF BLDG 3) W/HEATER CANNOT OPEN INTO LIVING SPACE |
|
| 05/16/2007 | BUILDING - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) ENTRANCE STOOP NEEDS TO BE 3' WIDE AND LENGTH OF DOOR OPENING AT DBL DOORS AND AT KITCHEN 2) OPEN GROUND ON OUTLET LAUNDRY ROOM 3) W/HEATER NEEDS SHEET METAL ON BOTTOM OF STAND 4) INSTALL 3 METAL SCREWS ON DBL B-VENT CONNECTION 5) COMBUSTION AIR NOT TO CODE 6) TRAP NOT INSTALLED ON A/C UNIT 7) A/C DISCONNECT NEEDS TO BE RELOCATED 8) LOWER CLEANOUT TO GRADE |