Permit: T06CM03116

Parcel: 123070950


Addresses:

1945 E MABEL ST

Inspection Status: Approved

Inspection History: EXT METAL CLIPS/EXT SHEATHING

Date Description Inspector Results Comments
10/25/2006 EXT METAL CLIPS/EXT SHEATHING Approved IVRS - Inspection :*
10/16/2006 EXT METAL CLIPS/EXT SHEATHING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) PER DETAIL 6/S4 A3.5 EACH TRUSS
2) BLOCK AND SCREW ALL SHEARWALL JOINTS
3) ADD SW1 OVER 25' ? WEST WALL AND EAST WALL
4) BLOCK SW2 JOINTS AND SCREW
5) PER DETAIL 7/S4 EACH END BRACING
6) INSTALL BRACING SOUTH GABLE TRUSSES KITCHEN
7) SHIM 3 POINT BEARING E01, E02
09/21/2006 EXT METAL CLIPS/EXT SHEATHING Partial Approval IVRS - Inspection :*