Permit: T06CM03104

Parcel: 108203300


Addresses:

4182 N FORTUNE LP

Inspection Status: Approved

Inspection History: PLUMBING - INTERMEDIATE

Date Description Inspector Results Comments
02/14/2007 PLUMBING - INTERMEDIATE Approved OK TO COVER TOILET ROOM AT FIREWALL
02/12/2007 PLUMBING - INTERMEDIATE Not ready for Inspection IVRS - Inspection :*
NO TEST
NO SUPPORT ON TRAP ARM
NO HANGERS ON OVERHEAD
12/21/2006 PLUMBING - INTERMEDIATE Partial Approval IVRS - Inspection :*
OK TO COVER ALL AREAS EXCEPT TOILET ROOM
NEXT TO STAIRWELL
11/14/2006 PLUMBING - INTERMEDIATE Partial Approval IVRS - Inspection :*
1. SCREW CLOSET FLANGES TO FLOOR
2. WASHER BOX TRAP TO BE 2X PIPE DIAMETER FROM WEIR TO POINT OF VENT.
3. AT KITCHEN SINK, HORIZONTAL X HORIZONTAL CHANGE OF DIRECTION TO BE A SWEEP.