Permit: T06CM03104

Parcel: 108203300


Addresses:

4182 N FORTUNE LP

Inspection Status: Approved

Inspection History: ELECTRIC - INTERMEDIATE

Date Description Inspector Results Comments
04/30/2007 ELECTRIC - INTERMEDIATE Approved IVRS - Inspection :*
01/02/2007 ELECTRIC - INTERMEDIATE Partial Approval IVRS - Inspection :*
OK CORRECTIONS, OK INTERIOR ELECTRICAL COVER
12/21/2006 ELECTRIC - INTERMEDIATE Not ready for Inspection WORK IN PROGRESS
11/15/2006 ELECTRIC - INTERMEDIATE Denied IVRS - Inspection :
See detailed listing on site.| 999*
1. SMOKE DETECTORS TO BE 3' AWAY FROM SUPPLY.
2. STRAP ROMEX WITHIN 12" OF BATHROOM EX. FAN.
3. CORRECT & SUPPORT ROMEX WIRING NEXT TO WASHER BOX SO IT DOES NOT STAND OUT OF WALL.
4. UNFINISHED ROMEX AT BATHROOM 1ST FLOOR NORTHSIDE.
5. 2ND FLOOR SUPER ROMEX OFF METAL FRAM SUPPORT OF RECESSED FIXTURE & STRAP ROMEX OF RECESSED FIXTURES.
6. SAME AS #1 ON 2ND FLOOR.