Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - GAS PRESSURE TEST
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 08/17/2006 | PLUMBING - GAS PRESSURE TEST | Approved | IVRS - Inspection :* | |
| 08/07/2006 | PLUMBING - GAS PRESSURE TEST | Partial Approval | IVRS - Inspection :* CALL MARCO 907-3773 15 PSI PRESSURE TEST IS OK PIPING PER PLAN OK WRAP ALL TOOL MARKS, THEN YOU CAN COVER |
|
| 08/03/2006 | PLUMBING - GAS PRESSURE TEST | Denied | IVRS - Inspection : See detailed listing on site.| 999* PIPE SIZE NOT PER PLAN USE A PRESSURE GAUGE WITH 1/10 PSI INCREMENTATIONS. INSTALL PIPING PLUMB, LEVEL AND SQUARE WITH NO BENDS OR STRAIN ON PIPING. SUPPORT PIPING AT 8' MAX WRAP ALL TOOL MARKS ON BELOW GRADE PIPING A SEDIMENT TRAP IS REQUIRED AT EQUIPMENT PROVIDE VENT CAP. |