Permit: T06CM03094


Addresses:

942 E VUELTA SUAVE

Inspection Status: Approved

Inspection History: EXT METAL CLIPS/EXT SHEATHING

Date Description Inspector Results Comments
10/09/2006 EXT METAL CLIPS/EXT SHEATHING Approved IVRS - Inspection :*
10/02/2006 EXT METAL CLIPS/EXT SHEATHING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) VENT FREEZE BOARDS
09/26/2006 EXT METAL CLIPS/EXT SHEATHING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) 6 X 6 WITH POST BASE REQUIRED AT ENTRY PORCH
2) VENTED FREEZE BOARDS REQUIRED AT C.P./L.A.
3) BLOCK TRUSSES AT C.P.
4) NAIL ROOF S.E. CORNER WHERE INDICATED
09/22/2006 EXT METAL CLIPS/EXT SHEATHING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) INSTALL RAT RUNS PER PLAN
2) PROVIDE SHEAR TRANSFER ROOF SHEATHING TO TOP PLATES-NAIL SHEATHING TO BIRD BOARDS-A35'S FROM BIRD BOARDS TO TOP PLATES
3) CABIN TIE FRONT PATIO
4) INSTALL PRESSURE BLOCKS BETWEEN TRUSSES BY CARPORT
5) CLIP CARPORT RAFTERS TO BEAM
6) TIGHTEN ALL RED HEADS
7) COMPLETE ROOF NAILING