Permit: T06CM03083

Parcel: 116260440

Inspection Status: Approved

Inspection History: BUILDING - FINAL

Date Description Inspector Results Comments
02/23/2007 BUILDING - FINAL Approved IVRS - Inspection :*
02/22/2007 BUILDING - FINAL Partial Approval IVRS - Inspection :*
1) NEED STUCCO AND INSULATION CERTS
02/21/2007 BUILDING - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) INSTALL GAS COCK AND PLUG REAR BBQ STUB
2) SECURE GAS PIPE H20 HEATER COMING OUT OF WALL
3) BACKFILL TRENCH AND COMPLETE GRADING
02/20/2007 BUILDING - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) NO ANSWER AT DOOR
2) NO ACCESS-RECALL
02/14/2007 BUILDING - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) ADJUST GARAGE DOOR TO SELF CLOSE
2) REMOVE OUTLET KITCHEN PENINSULA AT OVER HANG
3) COMPLETE ITEMS 3, 4, 6, 10 AND 11
4) PROTECT ROMEX GARAGE AND PIPE BARRIER INSIDE STUGGO (SUGEST SHEETROCK)
5) KITCHEN GFCI'S NOT TRIPPING
6) NEED CERTS
7) NEED VERIFICATION OF 03040, 03050 & 03055 APPROVAL
02/12/2007 BUILDING - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) BOND GAS LINE
2) SMOKIES REQUIRED ARC FAULT PROTECTION
3) EXTERIOR OUTLETS REQUIRED BUBBLE COVERS
4) 2" CLEARANCE REQUIRED UNDER WEEP SCREED AT PATIO
5) INSTALL DISHWASHER
6) OUTLET COVERS MISSING
7) COMPLETE PLUMBING AT BATH
8) INSTALL EXHAUST FANS
9) 1" CLEARANCE TO COMBUSTIBEL REQUIRED AT WATER HTR FLUE
10) SEDIMENT TRAP REQUIRED AT WATER HTR
11) GARAGE OUTLETS MUST BE GFI PROTECTED
12) SMOKIE NEEDED IN HALLWAY LEADING TO BEDROOMS
13) STOPPED INSPECTION