Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - INTERMEDIATE
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 08/31/2006 | PLUMBING - INTERMEDIATE | Approved | IVRS - Inspection :* | |
| 08/22/2006 | PLUMBING - INTERMEDIATE | Not ready for Inspection | IVRS - Inspection :* REGARDING TUB WASTE -- FURNCO NOT APPROVED USE SHIELDED COUPLING. ANY STUD OVER NOTCHED OR CUT TO BE REPAIRED WITH FHA STRAPS. |
|
| 08/21/2006 | PLUMBING - INTERMEDIATE | Not ready for Inspection | 1. PLEASE HAVE YOUR PLAN AND PERMIT ON SITE DISHWASHER HOSE TO BE SECURED WITHIN 2" OF DRAIN BOARD HEIGHT. 2. PLEASE CALL IN AND HAVE ALL APPROVED ALL REQUIRED INSPECTIONS PRIOR TO REQUESTING FINAL. |
|
| 08/07/2006 | PLUMBING - INTERMEDIATE | Not ready for Inspection | IVRS - Inspection :* DO NOT CALL INSPECTION UNTIL WORK IS COMPLETE STRAPPING FHA STRAPS SUPPORTS TUB WASTE NOT APPROVED |