Inspection History Details
Permit: T06CM03073
Inspection Status: Approved
Inspection History: ELECTRIC - FINAL
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 04/06/2007 | ELECTRIC - FINAL | Approved | IVRS - Inspection :* | |
| 04/05/2007 | ELECTRIC - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* |
|
| 04/03/2007 | ELECTRIC - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1. LABEL PANEL CKTS PER NEC 408 2. NO DEVICE INSTALLED ON BOX MASTER BDRM CLOSET 3. NO POWER TO SMOKE DETECTORS 4. MISSING TRIM ON CLOSET LIGHT 5. MISSING PLATE ON RECEPT FOR HOOD EXHAUST KITCHEN 6. BACK PORCH GFI RECEPT VERY LOOSE 7. NEED ACCESS TO ROOF TO INSPECT ROOFTOP UNIT 8. CHECK CIRCUIT REQUIREMENTS FOR KITCHEN COUNTERTOPS PER NEC 210.52(B) PLANS CALL FOR 1 CIRCUIT AT COUNTERTOP RECEPT & NEC REQUIRES 2 CIRCUITS. |