Permit: T06CM03073


Addresses:

4175 N FORTUNE LP

Inspection Status: Approved

Inspection History: ELECTRIC - FINAL

Date Description Inspector Results Comments
04/06/2007 ELECTRIC - FINAL Approved IVRS - Inspection :*
04/05/2007 ELECTRIC - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
04/03/2007 ELECTRIC - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
1. LABEL PANEL CKTS PER NEC 408
2. NO DEVICE INSTALLED ON BOX MASTER BDRM CLOSET
3. NO POWER TO SMOKE DETECTORS
4. MISSING TRIM ON CLOSET LIGHT
5. MISSING PLATE ON RECEPT FOR HOOD EXHAUST KITCHEN
6. BACK PORCH GFI RECEPT VERY LOOSE
7. NEED ACCESS TO ROOF TO INSPECT ROOFTOP UNIT
8. CHECK CIRCUIT REQUIREMENTS FOR KITCHEN COUNTERTOPS PER NEC 210.52(B)
PLANS CALL FOR 1 CIRCUIT AT COUNTERTOP RECEPT & NEC REQUIRES 2 CIRCUITS.