Permit: T06CM03068

Parcel: 13322471B

Inspection Status: Approved

Inspection History: PLUMBING - PROGRESS

Date Description Inspector Results Comments
10/12/2006 PLUMBING - PROGRESS Approved IVRS - Inspection :*
10/10/2006 PLUMBING - PROGRESS Denied IVRS - Inspection :
See detailed listing on site.| 999*
- WATER & DWV NOT UNDER TEST.
- RECONNECT 2" WASTE, INSTALL TEST PLUG, FILL W/WATER.
- 3" THREADED PLUG IN CEILING SHALL BE MADE WATER AND GAS TIGHT W/APPROVED THREAD SEALOUT.
- WATER SHALL BE ON, PIPING OK IF YOU ARE NOT CONCERNED THAT A PORTION OF IT IS OUT OF THE WALL, AND ALL JOINTS HAVE BEEN REAMED AND TUBING HAS BEEN INSTALLED PER UPC INSTALLATION STANDARDS.
ABS PIPE SHALL BE CUT SQUARE AND REAMED.