Permit: T06CM03052

Parcel: 12701001B


Addresses:

421 N ARCADIA AV


Inspection Status: Approved

Inspection History: REINFORCED MASONRY PRE-GROUT

Permit Number - T06CM03052

Inspection Description - REINFORCED MASONRY PRE-GROUT

Inspection Status - Approved

Date Description Inspector Results Comments
12/19/2006 REINFORCED MASONRY PRE-GROUT Approved IVRS - Inspection :*
ELEVATOR MECHANICAL ROOM @ 14'8" TOPPED OUT
12/18/2006 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
ELEVATOR EQUIPMENT ROOM #113 @ 4' -- OK TO GROUT
12/15/2006 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
NORTH ELEVATOR/STAIRWELL @ 30'8" -- OK TO GROUT
12/13/2006 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
NORTH ELEVATOR/STAIRWELL OK TO 28FT
12/11/2006 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
TOP OUT ON SOUTH STAIRWELL AT 30'8"
12/07/2006 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
SOUTH STAIRWELL @ 20' OK TO GROUT
12/06/2006 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
NORTH STAIRWELL & ELEVATOR SHAFT @ 24' OK TO GROUT
12/05/2006 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
SOUTH STAIRWELL @ 24' -- OK TO GROUT
12/04/2006 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
NORTH STAIRWELL & ELEVATOR SHAFT @ 20' OK TO GROUT
11/30/2006 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
SOUTH STAIRWELL @ 20' -- OK TO GROUT
11/29/2006 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
NORTH STAIRWELL @ 15'8"; B/1 TO C/1 @ 13'6" OK TO GROUT.
11/28/2006 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
B/1 TO C/1 @ 8' -- OK TO GROUT
11/22/2006 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
SOUTH STAIRWELL @ 13'4" ;
MECHANICAL ROOM LINTEL @ 13'4" -- OK TO GROUT
11/21/2006 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
NORTH STAIRWELL & ELEVATOR SHAFT @ 12' -- OK TO GROUT
11/16/2006 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
MECHANICAL ROOM TO 13'6" OK TO GROUT
11/15/2006 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
NORTH STAIRWELL @ 8'; ELEVATOR SHAFT @ 8' OK TO GROUT
11/14/2006 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
MECHANICAL ROOM #108 @ 8' (GROUTED); RESTROOM PARTITION WALLS OK TO GROUT.
11/13/2006 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
N&E WALLS @ 13'7" -- MECHANICAL ROOM @ 4'
OK TO POUR AREAS
11/09/2006 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
A/1 TO A/4, A/1 TO E/1, E/1 TO E/2 @ 12'; SOUTH STAIRWELL @ 8' OK TO GROUT.
11/07/2006 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
WEST WALL @ 13'7" -- NORTH WALL A/4 TO A3 @ 12'0"
OK TO POUR
11/06/2006 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
WEST WALL @ 12' OK TO GROUT
11/01/2006 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
A/2 TO A/1
A/1 TO C/1 @ 8' OK TO GROUT
10/31/2006 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :$
N.WALL A1/A4 -- MAIN BLDG. EXCEPT FOR EAST WALL A/TO D1
STAIRWELLS & ELEVATOR
10/26/2006 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
ALL WALLS @ 4' EXCEPT INTERIOR WALLS OF MECHANICAL ROOM -- OK TO POUR
10/25/2006 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
1ST L 4'-0" GRIDLINE 1-4/THRU A
GRIDLINE A/1-4
4/A-D 1/2
1/A-E