Inspection History Details
Inspection Status: Approved
Inspection History: REINFORCED MASONRY PRE-GROUT
Permit Number - T06CM03052
Inspection Description - REINFORCED MASONRY PRE-GROUT
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
12/19/2006 | REINFORCED MASONRY PRE-GROUT | Approved | IVRS - Inspection :* ELEVATOR MECHANICAL ROOM @ 14'8" TOPPED OUT |
|
12/18/2006 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* ELEVATOR EQUIPMENT ROOM #113 @ 4' -- OK TO GROUT |
|
12/15/2006 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* NORTH ELEVATOR/STAIRWELL @ 30'8" -- OK TO GROUT |
|
12/13/2006 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* NORTH ELEVATOR/STAIRWELL OK TO 28FT |
|
12/11/2006 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* TOP OUT ON SOUTH STAIRWELL AT 30'8" |
|
12/07/2006 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* SOUTH STAIRWELL @ 20' OK TO GROUT |
|
12/06/2006 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* NORTH STAIRWELL & ELEVATOR SHAFT @ 24' OK TO GROUT |
|
12/05/2006 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* SOUTH STAIRWELL @ 24' -- OK TO GROUT |
|
12/04/2006 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* NORTH STAIRWELL & ELEVATOR SHAFT @ 20' OK TO GROUT |
|
11/30/2006 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* SOUTH STAIRWELL @ 20' -- OK TO GROUT |
|
11/29/2006 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* NORTH STAIRWELL @ 15'8"; B/1 TO C/1 @ 13'6" OK TO GROUT. |
|
11/28/2006 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* B/1 TO C/1 @ 8' -- OK TO GROUT |
|
11/22/2006 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* SOUTH STAIRWELL @ 13'4" ; MECHANICAL ROOM LINTEL @ 13'4" -- OK TO GROUT |
|
11/21/2006 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* NORTH STAIRWELL & ELEVATOR SHAFT @ 12' -- OK TO GROUT |
|
11/16/2006 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* MECHANICAL ROOM TO 13'6" OK TO GROUT |
|
11/15/2006 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* NORTH STAIRWELL @ 8'; ELEVATOR SHAFT @ 8' OK TO GROUT |
|
11/14/2006 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* MECHANICAL ROOM #108 @ 8' (GROUTED); RESTROOM PARTITION WALLS OK TO GROUT. |
|
11/13/2006 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* N&E WALLS @ 13'7" -- MECHANICAL ROOM @ 4' OK TO POUR AREAS |
|
11/09/2006 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* A/1 TO A/4, A/1 TO E/1, E/1 TO E/2 @ 12'; SOUTH STAIRWELL @ 8' OK TO GROUT. |
|
11/07/2006 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* WEST WALL @ 13'7" -- NORTH WALL A/4 TO A3 @ 12'0" OK TO POUR |
|
11/06/2006 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* WEST WALL @ 12' OK TO GROUT |
|
11/01/2006 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* A/2 TO A/1 A/1 TO C/1 @ 8' OK TO GROUT |
|
10/31/2006 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :$ N.WALL A1/A4 -- MAIN BLDG. EXCEPT FOR EAST WALL A/TO D1 STAIRWELLS & ELEVATOR |
|
10/26/2006 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* ALL WALLS @ 4' EXCEPT INTERIOR WALLS OF MECHANICAL ROOM -- OK TO POUR |
|
10/25/2006 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* 1ST L 4'-0" GRIDLINE 1-4/THRU A GRIDLINE A/1-4 4/A-D 1/2 1/A-E |