Inspection Status: Approved
Inspection History: PLUMBING - YARD WTR LINE/TEST
Permit Number - T06CM03032
Inspection Description - PLUMBING - YARD WTR LINE/TEST
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
08/23/2007 | PLUMBING - YARD WTR LINE/TEST | Approved | IVRS - Inspection :* | |
08/22/2007 | PLUMBING - YARD WTR LINE/TEST | Not ready for Inspection | IVRS - Inspection :* PROVIDE APPROVED SITE PLANS ON SITE FOR YARDWATER |
|
07/19/2007 | PLUMBING - YARD WTR LINE/TEST | Denied | IVRS - Inspection : See detailed listing on site.| 999* CONSTRUCTION WATER SHALL BE PROTECTED FROM BACKFLOW - REMOVE WATER HOSES OR I WILL HAVE YOUR METER LOCKED OFF. |
|
02/28/2007 | PLUMBING - YARD WTR LINE/TEST | Partial Approval | IVRS - Inspection :* 24 HR PSI AT 65 PSI ON YARD WATER FROM BUILDING SERVICE TO RP LOCATION OK STILL HAVE NOT SEEN AN APPROVED PLAN |
|
02/27/2007 | PLUMBING - YARD WTR LINE/TEST | Partial Approval | IVRS - Inspection :* 65 PSI ON GAUGE LEAVE PSI ON WITHOUT INTRODUCING ANY MORE AIR RECALL FOR INSPECTION, PROVIDE SITE PLAN |
|
02/14/2007 | PLUMBING - YARD WTR LINE/TEST | Partial Approval | IVRS - Inspection :* 2" TYPE K SERVICE W/BRAZED JOINT AT WATER SERVICE. |
|
02/06/2007 | PLUMBING - YARD WTR LINE/TEST | Partial Approval | IVRS - Inspection :* |