Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit: T06CM03008

Parcel: 132130570


Addresses:

1051 E BENSON HY 03


Inspection Status: Approved

Inspection History: EXCAVATION/LAYOUT REBAR & ZON

Permit Number - T06CM03008

Inspection Description - EXCAVATION/LAYOUT REBAR & ZON

Inspection Status - Approved

Date Description Inspector Results Comments
08/03/2007 EXCAVATION/LAYOUT REBAR & ZON Approved IVRS - Inspection :*
04/04/2007 EXCAVATION/LAYOUT REBAR & ZON Not ready for Inspection IVRS - Inspection :*
PROVIDE SPECIAL INSPECTIONS REPORT IN COMPLIANCE WITH THE SHOP DRAWING FOR MAIN STRUCTURAL FRAME TO SUPPORT SLAB ON DECK.
04/03/2007 EXCAVATION/LAYOUT REBAR & ZON Denied IVRS - Inspection :
See detailed listing on site.| 999*
04/02/2007 EXCAVATION/LAYOUT REBAR & ZON Denied IVRS - Inspection :
See detailed listing on site.| 999*
INCOMPLETE WORK
02/05/2007 EXCAVATION/LAYOUT REBAR & ZON Partial Approval IVRS - Inspection :*
1) SLAB 6" THICK WITH #5 REBAR AT 12" ON CENTER AND #4 AT 18" ON CENTER SHORT DIRECTION, ELEVATOR PIT DETAIL 33 ON SHEET SD2-OK TO POUR
01/17/2007 EXCAVATION/LAYOUT REBAR & ZON Partial Approval IVRS - Inspection :*
BASEMENT WALL 7 #5 HORIZ (1) #5 @ 24" O.C
TOP OF FOOTING (1) #5 2 24" O.C
VERTICALS #6 @ 16" O.C AND #5 @ 16" O.C
CONTINUOUS FOUNDATION 5' W X 1'6" D
GRIDLINE O/J-C, C/0-1, 1/C-A, A/1-13
13/A-C, C/13-14, 14/C-M, M/1-14