Permit: T06CM03001

Parcel: 107120690

Inspection Status: Approved

Inspection History: PLUMBING - FINAL

Date Description Inspector Results Comments
05/30/2008 PLUMBING - FINAL Approved
05/27/2008 PLUMBING - FINAL Not ready for Inspection IVRS - Inspection :*
1. CAULK ALL FIXTURES
2. POST NOTICE IN ELECTRIC SERVICE PANEL: "THIS BLDG HAS NON-METALLIC INTERIOR WATER PIPING"
3. INSTALL COUNTER SUNK TAPPED CLEANOUT PLUGS WITH MACHINE SCREWS AND LEAVE THE C.P COVERS OFF FOR INSPECTION
4. YOU MAY WISH TO CHECK YOUR T&P RELIEF DRAINS -
THEY NEED TO BE GRAVITY DRAIN
03/14/2008 PLUMBING - FINAL Not ready for Inspection IVRS - Inspection :*
CONNECT YARDWATER TO METER
03/13/2008 PLUMBING - FINAL Not ready for Inspection IVRS - Inspection :*
PLEASE CALL IN AND HAVE APPROVED ALL REQUIRED INSPECTIONS PRIOR TO CALLING FINAL

NOTE: CLEANOUTS ARE TO BE INSTALLED WITH CLEANOUT ADAPTORS AND PLUGS.
01/10/2008 PLUMBING - FINAL Not ready for Inspection IVRS - Inspection :*