Inspection Status: Approved

Inspection History: PLUMBING - INTERMEDIATE

Date Description Inspector Results Comments
01/10/2008 PLUMBING - INTERMEDIATE Approved IVRS - Inspection :*
06/28/2007 PLUMBING - INTERMEDIATE Partial Approval IVRS - Inspection :*
1. ARCHITECT APPROVED CSST
2. PLAN REVIEWER NEEDS TO LOOK AT REDLINED GAS PLAN
FOR DEVELOPED LENGTH AND BTU CONSUMPTION FOR BKL IP CSST
06/26/2007 PLUMBING - INTERMEDIATE Not ready for Inspection AVB'S ON HOSE BIBS
BLK IRON PIPE FOR GAS
PROTECTED PIPE THRU MASONRY
06/20/2007 PLUMBING - INTERMEDIATE Not ready for Inspection IVRS - Inspection :*
1. POST YOUR ADDRESS, BUILDING NUMBER AND UNIT NUMBERS
2. GAS PIPING MAY NOT BE DIRECTLY EMBEDDED IN CONCRETE
3. FILL TUBS ALL THE WAY UP
4. SECURE CLOSET FLANGES TO THE FLOOR
5. HORIZONTAL BY HORIZONTAL CHANGE OF DIRECTION
TO BE A SWEEP